Foam mounting COMPACT universal standard (12 x 0.35l)
– household foam of high density, which allows to carry out a wide range of household and household work on filling, voids, cracks, seams, installation of window and door blocks,
sealing, heat- and sound insulation of various rooms, structures without the use of special mounting guns.
Advantages:
• Economical filling and compact packaging for one-time work
• The ability to work without a gun directly from the cylinder
• The high density of the products provides excellent heat and
noise insulation
• Precise dosing and easy baking even without the presence of a professional tool
• Increased adhesion to porous and "complex" materials
• Universal formula for a wide range of applications for
various household, household and construction works
Features:
• Foam designed specifically for retail stores,
networks, for home household use without the use of any professional skills
• Household foam for compact packaging, convenient for reusable large
works, which should not be left in the balloon until the next application
Characteristics:
Odor: Light specific odor, has no odor in the solidified state
Color: Light beige with a yellowish tinge
Shelf life: 18 months
Application temperature: From -10°C to +35°C
Storage temperature range: From +5°C to +35°C
Temperature mode of transportation: -20°C to +35°C
Foam density: TM 1019:2014 41-43 kg/m3*
Time of formation of non-sticky surface film:TM 1014:2013 12-13 min.*
Time to start pruning: TM 1005-2013 35 min*
Full polymerization time: 24 hours
Secondary expansion: Max. 250 %**
Output per package: TM 1003-2013 Up to 15 l**
Heat resistance of the hardened foam: From -55°C to +90°C, short-term to +120°C
* At 20°C and rel. humidity 65% **At 23°C and rel. humidity 50%
Purpose:
Installation and sealing of window and door blocks; filling, sealing, sealing of holes, cracks and voids; fixing and insulation of pipes, technical and engineering communications;installation and sealing of wall panels, slopes, window sills; sealing, heat and noise insulation of premises, building and frame structures.
Before using:
- withstand the balloon for at least 12 hours at a temperature of +18 ° C - +20 ° C;
- shake the balloon vigorously for 30 seconds;
- remove the protective cover;
- screw the adapter with a polyethylene tube onto the balloon valve;
- turn the cylinder to the working position "BOTTOM UP"
Application:
The temperature of the cylinder during use: not lower than +18 ° C; working surfaces must be sufficiently moistened, cleaned of dust and dirt; apply foam by adjusting the output intensity
by pressing the adapter; take into account the dependence of the foam characteristics on environmental conditions;
foam volume increase: 1.5-2.5 times; time for polymerization depends on the conditions of the surrounding environment and is at least 6-8 hours with a seam width of 30 mm and a depth of 60 mm; primary
/>expansion - 70%, secondary - 150-250%; uncured foam is easily removed by universal MARCON foam cleaner or other solvents; frozen foam is removed only mechanically; to preserve the physical and mechanical properties of the foam for a long time,
in order to avoid its destruction, it is necessary to protect the foam from UV rays and atmospheric precipitation (with PSUL tapes, waterproofing tapes, specialized sealants,
mastics, plaster solutions, etc.); do not apply to the surface, covered with frost or ice.
It is forbidden to heat the aerosol can above +50 °C!
Composition:
Contains 4,4’ - diphenylmethanediisocyanate, polyol component, hydrocarbon propellant,
dimethyl ether. It does not contain ozone-depleting foaming agents. The volume of the cylinder is 650ml.
Filling volume 350 ml.
Disposal:
Do not burn the cylinder (even) empty, do not pierce, do not deform (do not crumple).
Dispose of the used balloon in a garbage container.
Storage and transportation:
Store and transport only in an upright position (with the valve facing up)! Cylinder
under pressure, do not open! Do not disassemble the balloon and do not give it to children! Store in a cool, dry place away from heat sources! Protect from direct sunlight
and heating above +50 °C! Storage temperature range: from +5°C to +35 °C. Temperature
mode of transportation: -20°C to +35°C.
Expiration date:
18 months from the date of manufacture (see the production date on the bottom of the cylinder).
Precautions:
Work in a well-ventilated area. In the rooms where spraying occurs,
smoke,do not use open windows and spark-forming equipment.Wear protective gloves and goggles before using
. The contents of the balloon may cause irritation of the eyes, respiratory organs, skin,allergic reactions.Avoid falling off the skin of the eye.If there is a fall,
rinse the skin with plenty of water. In case of contact with eyes, rinse immediately with water and consult a doctor. The foaming agent is heavier than air and belongs to combustible substances.
Do not spray near open flames and incandescent objects! FLAMMABLE!
No reviews found